Totalisatoren

Preisangaben in Euro:
Liefer- u. Zahlungskonditionen siehe AGB

Typ

Preis

Typ

Preis

Typ

Preis

101

408

101i*

508

PS

225

101a

500

101ai*

599

MC

167

101b

625

101bi*

724

BAT

43

101c

500

101ci*

599

101d

500

101di*

599

* Die mit * gekennzeichneten Typen sind nur für ATEX zertifizierte Signalgeber geeignet.

  • Display : Large LCD 40mm x 90mm, with seven
    17mm and eleven 8mm digits.
  • Control Buttons : Three touch buttons on U.V.
    resistant polyester key pad.
  • Casing  : High Impact, U.V. resistant, flameproof
    ABS – IP 66 case.
  • Dimensions : 130mm x 114mm x 71mm ( L x H x D ).
  • Operating Temperature  : - 20°C to +70°C. 
  • Configuration :Configuration is done at SET UP level.
  • Password  : All settings can be password protected.
  • Data Protection  : EEPROM back up of all settings.
    Accumulated Total backed up every minute.
  • Input Frequency  : 0.01 Hz to 10 kHz.
  • Selectable Units  : TOTAL : L, GAL, bbl ( barrels ), m3,
    kg, lb or no unit in 0.67" digits. 
  • FLOWRATE : L, GAL, bbl ( barrels ), cf, m3, kg, lb or
    no unit in 0.32" digits 
  • TIME UNITS : / second, / minute, / hour or / day .
  • Tag Number :A seven digit identification number can
    be entered for Screen notification
  • Environment :EMC compliant ref : EN50081 and EN50082.

Models

101 Totaliser and Flow rate Indicator

Features: Totaliser and Flow Rate indication with Linearisation
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V D.C. supply can be connected. 
Information: Total , Flow Rate , Accumulated Total and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable. 
101 I Suitable for Hazardous Area Installation . Eex ia IIC T4 .

101 a Totaliser and Flow Rate Indicator with Analogue and Pulse output

Features: Totaliser and Flow Rate indication with Linearisation.
4 – 20 mA output in relation to Flowrate.
Pulse output in relation to Accumulated Total.
 
Power: 3 V Lithium Battery (average life 5 years ), although an 8 – 28 V A.C. / D.C. supply or 4 – 20 mA loop ( 28 V max ) can be connected.
Information: Total, Flow Rate, Accumulated Total and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable. 
101 ai Suitable for Hazardous Area Installation. Eex ia IIB T4.

101 b Totaliser and Batch Controller with Pulse output

This Batch Controller is a straight forward device offering exactly what is required for the majority of applications. The operator can enter a reset batch value easily or execute repeated batches. During the batch run, the preset batch value is displayed as well as the batched quantity and units of measurement . An overrun correction ensures an accurate batch quantity. The running batch quantity ( 0.67" digits ) can be set to count up or down. Two transistor outputs are available for either 1) pulse output and one stage batch control or 2) two stage batch control.

Features: Preset Batch Value indication.
Overrun correction.
Pulse output mirroring count on display.
One or Two stage batch control.
 
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V A.C. / D.C. supply can be connected.
Information: Preset Batch Value, Quantity Batched, Total, Accumulated Total and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable. 
101 bi Suitable for Hazardous Area Installation. Eex ia IIB T4.

101 c Totaliser and Flow Rate Indicator with Critical Alarm output

Features: Totaliser and Flow Rate indication.
High and Low Alarm Flowrate Monitoring.
Two Alarm Outputs.
4 – 20 mA output in relation to Flowrate.
 
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V A.C. / D.C. supply can be connected.
Information: Total, Flow Rate, Accumulated Total, Alarm Points and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable. 
101 ci Suitable for Hazardous Area Installation . Eex ia IIB T4 .

101 d Totaliser , Flow Rate and Direction of Flow Indicator

Features: Totaliser and Flow Rate indication.
Quadrature input for bi–directional measurement.
4 – 20 mA output in relation to Flowrate.
Pulse output in relation to Accumulated Total.
Flow Direction output .
 
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V A.C. / D.C. supply can be connected.
Information: Total, Flow Rate, Accumulated Total, Flow Direction and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable. 
101 di Suitable for Hazardous Area Installation . Eex ia IIB T4 .

Options

PS: 80 – 230 V A.C. Power Supply
MC: Modbus Communication RS 485

Ordering

Order code: Model/ (Option)

e.g. 101a / PS