Preisangaben in Euro:
Liefer- u. Zahlungskonditionen siehe AGB.
Typ |
Preis |
Typ |
Preis |
Typ |
Preis |
101 |
408 |
101i* |
508 |
PS |
225 |
101a |
500 |
101ai* |
599 |
MC |
167 |
101b |
625 |
101bi* |
724 |
BAT |
43 |
101c |
500 |
101ci* |
599 |
||
101d |
500 |
101di* |
599 |
* Die mit * gekennzeichneten Typen sind nur für ATEX zertifizierte Signalgeber geeignet.
Models
101 Totaliser and Flow rate Indicator
Features: Totaliser and Flow Rate indication with Linearisation
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V D.C. supply can be connected.
Information: Total , Flow Rate , Accumulated Total and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable.
101 I Suitable for Hazardous Area Installation . Eex ia IIC T4 .
101 a Totaliser and Flow Rate Indicator with Analogue and Pulse output
Features: Totaliser and Flow Rate indication with Linearisation.
4 – 20 mA output in relation to Flowrate.
Pulse output in relation to Accumulated Total.
Power: 3 V Lithium Battery (average life 5 years ), although an 8 – 28 V A.C. / D.C. supply or 4 – 20 mA loop ( 28 V max ) can be connected.
Information: Total, Flow Rate, Accumulated Total and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable.
101 ai Suitable for Hazardous Area Installation. Eex ia IIB T4.
101 b Totaliser and Batch Controller with Pulse output
This Batch Controller is a straight forward device offering exactly what is required for the majority of applications. The operator can enter a reset batch value easily or execute repeated batches. During the batch run, the preset batch value is displayed as well as the batched quantity and units of measurement . An overrun correction ensures an accurate batch quantity. The running batch quantity ( 0.67" digits ) can be set to count up or down. Two transistor outputs are available for either 1) pulse output and one stage batch control or 2) two stage batch control.
Features: Preset Batch Value indication.
Overrun correction.
Pulse output mirroring count on display.
One or Two stage batch control.
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V A.C. / D.C. supply can be connected.
Information: Preset Batch Value, Quantity Batched, Total, Accumulated Total and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable.
101 bi Suitable for Hazardous Area Installation. Eex ia IIB T4.
101 c Totaliser and Flow Rate Indicator with Critical Alarm output
Features: Totaliser and Flow Rate indication.
High and Low Alarm Flowrate Monitoring.
Two Alarm Outputs.
4 – 20 mA output in relation to Flowrate.
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V A.C. / D.C. supply can be connected.
Information: Total, Flow Rate, Accumulated Total, Alarm Points and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable.
101 ci Suitable for Hazardous Area Installation . Eex ia IIB T4 .
101 d Totaliser , Flow Rate and Direction of Flow Indicator
Features: Totaliser and Flow Rate indication.
Quadrature input for bi–directional measurement.
4 – 20 mA output in relation to Flowrate.
Pulse output in relation to Accumulated Total.
Flow Direction output .
Power: 3 V Lithium Battery ( average life 5 years ), although an 8 – 28 V A.C. / D.C. supply can be connected.
Information: Total, Flow Rate, Accumulated Total, Flow Direction and measurement units.
# Total can be reset to zero. Accumulated Total is not resettable.
101 di Suitable for Hazardous Area Installation . Eex ia IIB T4 .
Options
PS: 80 – 230 V A.C. Power Supply
MC: Modbus Communication RS 485
Ordering
Order code: Model/ (Option)
e.g. 101a / PS