Lx Liquid Turbine Flowmeters

Liefer- u. Zahlungskonditionen siehe AGB.
Tabellenpreisangaben in Euro bei Einzelabnahme:

Größe

BSP & NPT

FL1 & FL3

FL2 & FL4

WAF

TRI

Internals Kit

1/2"

624

308

5/8" & 3/4"

639

770

832

662

770

339

1"

708

816

893

716

816

416

1 1/2"

747

881

963

785

881

447

2"

816

963

1047

862

963

516

3"

1263

1348

1155

639

4"

1879

2017

1001

6"

2641

2849

1417

  • Materials
    Body : 316 Stainless Steel
    Rotor Supports : 316 Stainless Steel
    Journal Bearings : Tungsten Carbide
    Thrust Ball: 316 Stainless Steel
    Rotor : ANC1A Stainless Steel
    Rotor Shaft :  Tungsten Carbide
  • Performance
    Linearity: +/- 0.5% (better than +/- 0.2%
    when used with "101" Totaliser)
    Repeatability: +/- 0.1%
    Temperature: -30°C to +120°C (maximum +350°C
    with optional High temperature Pick Up )
    Pressure Drop: 250 mbar at maximum quoted Flow rate
  • Style
    BSP : BSPP male Threaded
    NPT : NPT male Threaded
    FL1 : ANSI 150 Flanged
    FL2 : ANSI 300 Flanged
    FL3 : BS 4504 (DIN) PN16
    FL4 : BS 4504 (DIN) PN25
    WAF : Wafer
    TRI : Tri - Clamp
  • Options
    HT: High Temperature Pick Up.
    IS: Intrinsically Safe Pick Up (ATEX certificated).
    2P: Second Pick Up fitted.

The Lx range of Turbine Flowmeters meet the demand of most liquid measurement applications.

They basically comprise of three component assemblies, fitted inside a stainless steel body (locked with an internal circlip), which has a magnetic pick up fitted and come in a range of threaded, flanged or wafer (designed for between flange installations) styles.

The Rotor & Shaft assembly (1 off) which is mounted between journal bearings inside the Rotor Shaft Support assemblies (2 off) is turned by the kinetic energy of the flowing fluid at an angular velocity, which in the linear range of the Flowmeter is proportional to the mean axial velocity of the fluid.

The Rotor blades sweep out the full bore of the meter except for a small tip clearance space. As the blade tips pass the magnetic pick up they initiate a pulse. Flow rate is determined by the frequency of the pulses and Totalised Flow is obtained by summing the pulses.

“101“ Totalisers, which sum the pulses automatically and display Flow Rate and Total Flow instantly on the readout, can be mounted on the Turbine or fitted remotely.

Ordering

Order code: Lx / Style /Size / (Option)

e.g. Lx / WAF / 2 "/ HT

Internal Kits (calibrated) can be supplied. These are very easy to retrofit into an existing Body on location (eliminating the need to return to the Turbine).

Lx Internal Kit Order code: Lx / Style /Size

e.g. Lx / NPT / 1/2